Introduction
KydroPro 100 Handheld Multiparameter Water Quality Sensor and KydroPro instrument for the measurement of pH, ORP, optical dissolved oxygen, conductivity, turbidity, temperature, salinity and more. KydroPro sensor allows for measurement of up to 5 parameters. They are automatically recognized by KydroPro instrument when connected. A backlit display, brief interfaces, simple operation keyboard, convenient calibration procedures, rechargeable battery, large log memory and powerful PC data program (Meter Read) make the instrument user friendly.
The dissolved oxygen sensor adopts the internationally leading fluorescence lifetime technology, which is based on the quenching principle of specific substances to active fluorescence in physics. The remarkable advantage of this fluorescence method in measuring dissolved oxygen is that it does not consume oxygen in the measurement process, so there is no flow rate limit, no need to preheat electrolyte, no need for maintenance and frequent calibration. The response time of Kacise optical dissolved oxygen probe is as low as 30 seconds, making the measurement of dissolved oxygen more accurate, more stable, faster and more convenient.
Dimensions
Specifications
KydroPro Water Quality Sensor Specifications |
||
Optical dissolved oxygen Sensor | Range | 0-20mg/L or 0-200% air Sat. |
Accuracy | 0- 200%:±1% | |
Resolution | 0.01mg/L | |
Calibration method | One or Two point | |
Turbidity Sensor | Range | 0.1-1000NTU |
Accuracy | ±5% or ±0.3NTU | |
Resolution | 0.1 NTU | |
Calibration method | Zero, One or Two point | |
4-electronic conductivity Sensor | Range | 1uS/cm~100mS/cm or 0~5mS/cm |
Accuracy | ±1% | |
Resolution | 1uS/cm~100mS/cm: 0.01mS/cm
0~5mS/cm: 0.01uS/cm |
|
Calibration method | One or Two point | |
pH Sensor | Range | pH: 0~14 |
Accuracy | ±0.1 | |
Resolution | 0.01 | |
Calibration method | Three point | |
Salinity Sensor | Range | 0~80ppt |
Accuracy | ±1ppt | |
Resolution | 0.01 ppt | |
Calibration method | One or Two point | |
Algae sensor | Range | 0~270,000 cells/ml |
Lower distinguish threshold | 300cells | |
Resolution | 1 cells/ml | |
Chlorophyll sensor | Range | 0-500ug/L or 0-100RFU |
Resolution | 0.1ug/L | |
Temperature | Range | 0~50℃ |
Accuracy | ±0.2℃ | |
Resolution | 0.01℃ | |
Other specifications | Housing IP Rating | IP68 |
Size | Φ22×166mm | |
Other specifications | Communication protocol | RS-485, MODBUS |
Power Requirements | DC 5~12V,current<50mA | |
Size | 220 x 96 x 44mm | |
Weight | 460g | |
Power | Two 18650 rechargeable batteries | |
Storage temperature | -40~85℃ | |
Display | 54.38 x 54.38LCD back illuminated | |
Data storage | Support | |
Pressure compensation range | Built-in,auto compensation in 50~115kPa | |
IP rating | IP68 | |
Regular Shutoff | Support |