Introduction
Kacise applies fiber technology to the turbidity sensor to make the sensor has better repeatability and stability, not susceptible to ambient light coordination. The sensor’s automatic cleaning brush effectively eliminates air bubbles and reduces the effects of contamination on the measurement. Long-term online use, longer maintenance intervals and better stability.
Feature
- Digital fiber optic turbidity sensor, RS-485 output, support MODBUS
- With automatic cleaning brush, prevent pollution, eliminate air bubbles
- Strong anti-interference ability, no ambient light and chromaticity
- 90° scattered light principle, better fiber technology repeat-ability
Technical Specifications
Principle | 90° scattered light |
Measuring Range | 0.1-1000NTU |
Resolution | 0.1NTU |
Accuracy | <5% or 0.3NTU |
Protection Rate | IP68 |
Max. Pressure | 6 bar |
Temperature Range | 0 ~ 50℃ |
Output | Support RS-485, MODBUS protocol |
Power Supply | DC 12~24V, current <100mA |
Installation | Input type |
Size | Φ36mm*198.2mm |
Material | Titanium |
Self-Cleaning System | Yes |
Optical Window | optical fiber |
Wiring
Red—Power (VCC)
White—485B
Green—485A
Black—Ground (GND)
Bare wire—shield