Sale!

KANN300 Series online Ammonia-nitrogen/nitrate nitrogen analyzer

KANN300 online Ammonia-nitrogen/nitrate nitrogen analyzer is an online water quality analyzer developed based on digital water quality analysis platform. Integrated design, using industrial online ion selective electrode, digital, intelligent analyzer design concept. The functions of electrode signal detection, temperature detection, automatic compensation and digital signal conversion are realized in the instrument. RS485 signal output, easy networking, and system integration, widely used in surface water, pollution sources and other industries.

Introduction

KANN300  online Ammonia-nitrogen/nitrate nitrogen analyzer is an online water quality analyzer developed based on digital water quality analysis platform. Integrated design, using industrial online ion selective electrode, digital, intelligent analyzer design concept. The functions of electrode signal detection, temperature detection, automatic compensation and digital signal conversion are realized in the instrument. RS485 signal output, easy networking, and system integration, widely used in surface water, pollution sources and other industries.

online Ammonia-nitrogen/nitrate nitrogen analyzer

 Characteristics

Integrated design, anti-electromagnetic interference Industrial online ion-selective electrode, can work stably for a long time Multi-parameter compensation algorithm of pH, temperature, potassium ion (K ) or chloride ion (Cl -) Built-in Air Purge automatic cleaning system, greatly reducing the maintenance workload Stainless steel case, IP68 waterproof grade, suitable for various working conditions RS485 signal output, Standard Modbus protocol, easy integration, networking.

Technical Specifications

Model number KANN300A KANN300B KANN300C
Measurement parameter NH4-N,pH,

temperature,

NH4-N,pH,

temperature,

NH4-N,pH,

temperature,

NO3-N NO3-N,K NO3-N,Cl-
Method of measurement Ion selective electrode method
Measurement mode Immersion measurement
Measuring range NH4-N:(0.1-1) mg/l, (1-10) mg/l, (10-100) mg/l, (100-1000) mg/L

NO3-N:(0.1-1) mg/l, (1-10) mg/l, (10-100) mg/l, (100-1000) mg/L

K :(1~1000) mg/L Cl-:(1~1000) mg/L PH:0~14

Temperature:(0~60)°C

Accuracy ≤ ± 3%
Repeatability ≤2%
Resolution NH4-N (minimum range) :0.01 mg/L

NO3-N (minimum range) :0.01 mg/L

Ph: 0.01  k : 0.01 mg/L CL-: 0.01 mg/L

Detection limit 0.1 mg/L
Response time ≤60s
Zero Drift (24h) ≤3% F.S.
Range Drift (24h) ≤3% F.S.
Calibration period Three months
Temperature range (0 ~ 60) °C
Protection level IP68
Cleaning mode Compressed air bar
MTBF ≥1440h/Time
Means of communication RS485(Modbus RTU), maximum baud rate 115200 bps
Supply voltage (12/24) V DC
Power consumption < 0.5W
Material Quality Stainless steel, POM
Weight 1.0 kg
Contour dimension 270 mm × φ60 mm
Water Quality monitor Redefining Standards Assessment
water quality monitor

Water Quality monitor Redefining Standards Assessment

In an ever-changing world where environmental concerns are at the forefront of our collective consciousness, the need for precise and dependable tools to safeguard our most precious resource—water—has never been more crucial. Enter the Water Quality Monitor, a technological marvel that stands as a sentinel of liquid purity in an age where water quality is

Read More »
Unveiling the KWS800 Water Quality Monitoring System
sensor

Unveiling the KWS800 Water Quality Monitoring System

Water is a vital resource that sustains life on Earth, and its quality is a cornerstone of environmental health. As human activities continue to impact water bodies, the need for effective water quality monitoring system has never been more pronounced. These systems play a pivotal role in assessing, preserving, and improving the condition of water

Read More »

Can turbidity measured by COD sensor replace TSS sensor

In the field of environmental monitoring and water quality analysis, it is crucial to find accurate and cost-effective detection methods. Chemical oxygen demand (COD) and total suspended solids (TSS) are two important indicators for assessing the degree of water pollution. This article will explore a fascinating question: Can turbidity measured by COD sensor replace TSS

Read More »

Thank you for reaching out for us!

Your inquiry will be responseed in 12 hours normally.
For any urgent case, you can contact us via whatsapp or phone.

whatsapp
Tel
thank-you